Ga naar hoofdinhoud

MQTT-gegevenspunten

cJson PointcJson Value typeR/WUnitPoint DescriptionEnum DefinitionAnnotation
AC Output / Settings
11009NumRWACchargeSpeedCharging Power Limit Range: 100-10800
11009UINTWACchargeSpeedCharging Power Limit Range: 100-10800
2618NumRGridChargeEnable1000:Disable
1001:Enable
Grid Charging Enable (0 = Disable, 1 = Enable)
2618EnumWGridChargeEnable0:Disable
1:Enable
Grid Charging Enable (0 = Disable, 1 = Enable)
AC Output / Real Time Data
2278FloatRWACOutWTotal AC Power = INV Power (positive when charging, negative when discharging) + Bypass Power (positive for EPS, negative for microinverter).
2600NumRVGrid voltageAC Input Voltage. Independent of charging/discharging status. Can be used for grid voltage detection. (uplink register)
2612NumRHzGrid voltageAC Input Frequency. Independent of charging/discharging status. Can be used for grid frequency detection.
AC Output / Info
11032NumRWOn Grid rated powerRated grid-connected output power. This represents the maximum active output power of the inverter.
Battery / Info
1109StringRBMS Master VersionMaster BMS software version. Parse the decimal value directly (e.g. 14501 → V1.45.01).
1120StringRMPPT VersionMPPT software version. Parse the decimal value directly (e.g. 14501 → V1.45.01).
6010NumRMaximum number of stringsMaximum number of battery modules supported by the current system.
142NumRkWhRated Capacity(Wh)Total battery capacity of the system. The value is the combined capacity of all battery modules and depends on both the number and type of battery modules installed.
114NumRWMaximum charge powerMaximum battery charging capability. This value is obtained from the battery and represents the maximum charging power supported by the battery.
115NumRWMaximum discharge powerMaximum system discharge active power. The maximum output active power is dynamically limited by both the inverter rating and the battery capability. For example, if the inverter is rated at 2400 W and four battery modules can each provide 1 kW, the total battery output is 4 kW, but the system output is limited to 2400 W by the inverter rating.
1136StringRDCDC_slaver1_VersionSlave DCDC1 software version. Parse the decimal value directly (e.g. 14501 → V1.45.01).
1137StringRBMS_slaver1_VersionSlave BMS1 software version. Parse the decimal value directly (e.g. 14501 → V1.45.01).
1138StringRDCDC_slaver2_VersionSlave DCDC2 software version. Parse the decimal value directly (e.g. 14501 → V1.45.01).
1139StringRBMS_slaver2_VersionSlave BMS2 software version. Parse the decimal value directly (e.g. 14501 → V1.45.01).
1140StringRDCDC_slaver3_VersionMaster DCDC3 software version. Parse the decimal value directly (e.g. 14501 → V1.45.01).
1141StringRBMS_slaver3_VersionSlave BMS3 software version. Parse the decimal value directly (e.g. 14501 → V1.45.01).
1142StringRDCDC_slaver4_VersionSalve DCDC4 software version. Parse the decimal value directly (e.g. 14501 → V1.45.01).
1143StringRBMS_slaver4_VersionSlave BMS4 software version. Parse the decimal value directly (e.g. 14501 → V1.45.01).
9008StringRSNMaster battery module serial number.
9032StringRSNSlave battery module 1 serial number.
9051StringRSNSlave battery module 2 serial number.
9070StringRSNSlave battery module 3 serial number.
9165StringRSNSlave battery module 4 serial number.
9218StringRSNSlave battery module 5 serial number.
1098StringRDCDC_slave5_VersionSlave DCDC5 software version. Parse the decimal value directly (e.g. 14501 → V1.45.01).
1099StringRBMS_slave5_VersionSlave BMS5 software version. Parse the decimal value directly (e.g. 14501 → V1.45.01)
Battery / Settings
6105NumR%BackUpSocBackup SOC (%) Range:0-100
6505UINTWBackUpSocBackup SOC (%) Range:0-100
Battery / Statistics
6006NumRkWhB Charge EnergyTotal Battery Charge Energy
6007NumRkWhB disCharge EnergyTotal Battery Discharge Energy
11019NumRminChargeLeftTimeRemaining Charging Time (min)
11020NumRminDischargeLeftTimeRemaining Discharging Time (min)
9003NumRNCycMaster Battery Pack Cycle Count
9019NumRNCycSlave Battery Pack 1 Cycle Count
9038NumRNCycSlave Battery Pack 2 Cycle Count
9057NumRNCycSlave Battery Pack 3 Cycle Count
9152NumRNCycSlave Battery Pack 4 Cycle Count
9205NumRNCycSlave Battery Pack 5 Cycle Count
6004NumRkWhDay_B Charge EnergyDaily Battery Charge Energy
6005NumRkWhDay_B disCharge EnergyDaily Battery Discharge Energy
Battery / Real Time Data
9002NumR%SoHMaster Battery Pack SOH
9004NumRVVMaster Battery Pack Voltage
9013NumRAAMaster Battery Pack Current
9018NumR%SoHSlave Battery Pack 1 SOH
9020NumRVVSlave Battery Pack 1 Voltage
9028FloatRCellTmpMinSlave Battery Pack 1 Minimum Cell Temperature
19173NumRAASlave Battery Pack 1 Current (uplink register)
9037NumR%SoHSlave Battery Pack 2 SOH
9039NumRVVSlave Battery Pack 2 Voltage
9047FloatRCellTmpMinSlave Battery Pack 2 Minimum Cell Temperature
19174NumRAASlave Battery Pack 2 Current (uplink register)
9056NumR%SoHSlave Battery Pack 3 SOH
9058NumRVVSlave Battery Pack 3 Voltage
9066FloatRCellTmpMinSlave Battery Pack 3 Minimum Cell Temperature
19175NumRAASlave Battery Pack 3 Current
9151NumR%SoHSlave Battery Pack 4 SOH
9153NumRVVSlave Battery Pack 4 Voltage
9161FloatRCellTmpMinSlave Battery Pack 4 Minimum Cell Temperature
19176NumRAASlave Battery Pack 4 Current (uplink register)
6000NumRWBatteryPowerTotal Battery Pack Charge/Discharge Power. Positive = Discharging; Negative = Charging.
9081FloatRelectric heating temperatureMaster Battery Pack Heater Temperature
9082NumRelectric heating powerMaster Battery Pack Heater Power
9097FloatRelectric heating temperatureSlave Battery Pack 1 Heater Temperature
9098NumRWelectric heating powerSlave Battery Pack 1 Heater Power
9113FloatRelectric heating temperatureSlave Battery Pack 2 Heater Temperature
9114NumRWelectric heating powerSlave Battery Pack 2 Heater Power
9129FloatRelectric heating temperatureSlave Battery Pack 3 Heater Temperature
9130NumRWelectric heating powerSlave Battery Pack 3 Heater Power
9145FloatRelectric heating temperatureSlave Battery Pack 4 Heater Temperature
9146NumRWelectric heating powerSlave Battery Pack 4 Heater Power
9204NumR%SoHSlave Battery Pack 5 SOH
9206NumRVVSlave Battery Pack 5 Voltage
9214NumRCCellTmpMinSlave Battery Pack 5 Minimum Cell Temperature
9267FloatRAASlave Battery Pack 5 Current (uplink register)
19177NumRAASlave Battery Pack 5 Current (uplink register)
9280FloatRelectric heating temperatureSlave Battery Pack 5 Heater Temperature
9281EnumRWelectric heating powerSlave Battery Pack 5 Heater Power
9405NumR%Total SOC(Full-system SoC)System SOC
Battery / Real Time State
6001EnumRBatteryState1000:Static
1001:Charging
1002:Discharging
Overall Battery Pack Operating Status
9079EnumRDC/DC state0:Standby
1:Charging
2:Discharging
3:Protection
Master Battery Pack DC/DC Status
9080EnumRelectric heating state0:Off
1:On
Master Battery Pack Heater Status
9095EnumRDC/DC state0:Standby
1:Charging
2:Discharging
3:Protection
Slave Battery Pack 1 DC/DC Status
9096EnumRelectric heating state0:Off
1:On
Slave Battery Pack 1 Heater Status
9111EnumRDC/DC state0:Standby
1:Charging
2:Discharging
3:Protection
Slave Battery Pack 2 DC/DC Status
9112EnumRelectric heating state0:Off
1:On
Slave Battery Pack 2 Heater Status
9127EnumRDC/DC state0:Standby
1:Charging
2:Discharging
3:Protection
Slave Battery Pack 3 DC/DC Status
9128NumRelectric heating stateSlave Battery Pack 3 Heater Status
9143EnumRDC/DC state0:Standby
1:Charging
2:Discharging
3:Protection
Slave Battery Pack 4 DC/DC Status
9144EnumRelectric heating state0:Off
1:On
Slave Battery Pack 4 Heater Status
9278EnumRDC/DC state0:Standby
1:Charging
2:Discharging
Slave Battery Pack 5 DC/DC Status
9279EnumRelectric heating state0:Off
1:On
Slave Battery Pack 5 Heater Status
Bypass / Statistics
9284NumRWhAC OUT discharge energyTotal Bypass Port Discharge Energy
9285NumRWhDay - AC OUT discharge energyDaily Bypass Discharge Energy
11034NumRWhMicroinverter generation energyTotal Microinverter Energy Generation
11035NumRWhDay Microinverter generation energy0:Off
1:On
Daily Microinverter Energy Generation
Bypass / Settings
680NumRBypass enable0:Disable
1:Enable
Off-grid & Bypass Enable
64100EnumRkey load enable0:Disabled
1:Enabled
Critical Load Enable (higher priority than Smart Meter and Smart Socket)
Bypass / Real Time Data
667FloatRWBypass  powerBypass Power
Bypass / Real Time State
11039NumRBypass  mode0:Eps
1:M-Inv
Bypass Mode (The EMS automatically detects the current direction to determine the operating mode.),0: EPS Mode;1: Microinverter Mode
Cluster / Settings
669EnumRsystem  Parallel Type0:Centralized (One Grid Connection Point)
1:Coordinated (Multiple Grid Connection Points)
Cluster Type
Grid / Settings
11010NumRWFeedBack PowerMaximum Grid Feed-in Power.Range: 0-10800
11010UINTWFeedBack PowerMaximum Grid Feed-in Power.Range: 0-10800
Inverter / Info
1119StringRInverter VersionInverter software version. Parse the decimal value directly and display it in the format Vx.xx (e.g. 108 → V1.08).
4NumRWRated output powerMaximum rated output power of the inverter.
614NumRWMaximum active powerMaximum active output power of the system. The maximum output active power is dynamically limited by both the inverter rating and the battery capability. For example, if the inverter is rated at 2400 W and four battery modules can each provide 1 kW, the total battery output is 4 kW, but the system output is limited to 2400 W by the inverter rating. Currently,
11028NumRVOff Grid rated voltageRated off-grid inverter voltage.
11029NumRHzOff Grid rated frequencyRated off-grid inverter frequency.
11030NumRWOff Grid rated powerRated off-grid output power.
Inverter / Real Time Data
2086NumRAAphAINV input current when charging; INV output current when not charging. No direction indication (always positive).
2083NumRVPhVphAINV input voltage when charging; INV output voltage when not charging. Not intended for grid voltage detection.
2095NumRHzHzINV input frequency when charging; INV output frequency when not charging. Not intended for grid frequency detection.
2098FloatRVAVA0 when INV is charging; otherwise, INV AC apparent output power.
2097FloatRVarVArAC Reactive Power
2099FloatR%PF0 when INV is charging; otherwise, INV AC output power factor.
2275FloatRWINV input powerINV AC input/output power with direction. Positive = AC input (charging); Negative = AC output (discharging). Replaces the definition of register 114.
Inverter / Event
8100EnumREvt11:DC Side Overvoltage
2:AC Connection Disconnected
3:DC Connection Disconnected
4:Grid Connection Disconnected
5:Ground Fault
6:AC Output Short Circuit
7:Inverter Overtemperature
8:Inverter Overfrequency
9:Inverter Underfrequency
10:AC Input Overvoltage
11:AC Input Undervoltage
12:Inverter Input Short Circuit
13:Inverter Low Temperature
19:Off-grid Inverter Phase A Overvoltage
20:Off-grid Inverter Phase A Undervoltage
21:Off-grid Inverter Phase A Overcurrent / Overload
INV Fault 1
Inverter / Statistics
11007NumRWhAC_WH_inputTotal INV Input Energy
2107NumRkWhActInWhTotal INV Charging Energy (calculated from INV input power)
11036NumRWhDay  On_Grid output energyDaily Grid-connected Discharge Energy (INV output energy)
11037NumRWhDay  Off_Grid output energyDaily Off-grid Discharge Energy (INV output energy)
Inverter / Settings
11011NumRWAC max discharge powerMaximum INV Output Power.Range:0-3600
Load / Real Time Data
5000FloatRWHomeUseWHome Load Power
Meter / Real Time State
7120EnumRWMeterState1000:Enable
1001:Disable
Meter Status
Meter / Real Time Data
11016FloatRWMeterPuMeter Phase U Power
15203INTWWMeterPuMeter Phase U Power
15204INTWMeterPuMeter Phase U Power
PV / Info
120NumRMaximum MPPT ChannelsMaximum number of MPPT inputs. ECO/AC versions report 0, while PV-enabled versions report 4.
11031NumRWMPPT rated powerRated MPPT power.
PV / Statistics
1502NumRkWhWHPV Daily Energy Generation
PV / Real Time Data
1632NumRADCAPV1 Current
1600NumRVDCVPV1 Voltage
1664NumRWDCWPV1 Power
1633NumRADCAPV2 Current
1601NumRVDCVPV2 Voltage
1665NumRWDCWPV2 Power
8500NumRPV total powerTotal PV Charging Power
1634NumRADCAPV3 Current
1602NumRVDCVPV3 Voltage
1666NumRWDCWPV3 Power
1635NumRADCAPV4 Current
1603NumRVDCVPV4 Voltage
1667NumRWDCWPV4 Power
PV / Real Time State
7119EnumRDCSt1:Powered Off
2:Sleep
3:Starting
4:Running
5:Power-Limited Operation
6:Shutting Down
7:Fault
8:Standby
9:Test Mode
PV1 Operating Status
7124EnumRDCSt1:Powered Off
2:Sleep
3:Starting
4:Running
5:Power-Limited Operation
6:Shutting Down
7:Fault
8:Standby
9:Test Mode
PV2 Operating Status
7126EnumRDCSt1:Powered Off
2:Sleep
3:Starting
4:Running
5:Power-Limited Operation
6:Shutting Down
7:Fault
8:Standby
9:Test Mode
PV3 Operating Status
7127EnumRDCSt1:Powered Off
2:Sleep
3:Starting
4:Running
5:Power-Limited Operation
6:Shutting Down
7:Fault
8:Standby
9:Test Mode
PV4 Operating Status
PV / Event
8138EnumRDCEvt1:PV Input Overvoltage
3:PV Input Disconnected
12:PV Module Input Short Circuit
13:PV Module Low Temperature
19:PV Input Reverse Polarity
21:PV Input Undervoltage
PV1 Alarm Code
8102EnumRDCEvt1:PV Input Overvoltage
3:PV Input Disconnected
12:PV Module Input Short Circuit
13:PV Module Low Temperature
19:PV Input Reverse Polarity
21:PV Input Undervoltage
PV2 Alarm Code
8132EnumRDCEvt1:PV Input Overvoltage
3:PV Input Disconnected
12:PV Module Input Short Circuit
13:PV Module Low Temperature
19:PV Input Reverse Polarity
21:PV Input Undervoltage
PV3 Alarm Code
8133EnumRDCEvt1:PV Input Overvoltage
3:PV Input Disconnected
12:PV Module Input Short Circuit
13:PV Module Low Temperature
19:PV Input Reverse Polarity
21:PV Input Undervoltage
PV4 Alarm Code
Socket / Real Time State
18000EnumWSmartSocketState0:Disconnected
1:Connected
Smart Socket Status
Socket / Real Time Data
18001UINTWSmartSocketPSmart Plug Power
System / Info
1118StringREMS VersionEMS software version. Parse the decimal value directly (e.g. 14501 → V1.45.01).
1127NumRModbus VersionPlatform protocol version. Used to identify the platform protocol version supported by the device. Parse the decimal value directly (e.g. 15 → V1.5).
System / Real Time State
11006EnumRSt1:Powered Off
2:Sleep
3:Starting
4:MPPT Operating
5:Current Limiting
6:Shutting Down
7:INV Fault
8:Standby
9:Grid Charging
10:Grid Discharging
11:Off-grid Charging
12:Off-grid Discharging
13:Low Battery Charging (charge battery to Backup SOC)
14:Deep Sleep
15:Scheduled Full Charge (force battery charging to 100%)
16:Off-grid Deep Sleep
System Operating Status
System / Settings
11008NumRTime year-month
Time day-hour
Time min-sec
Date (Year/Month),High byte: Year (2000-based), range 0–99; Low byte: Month, range 1–12
Date (Day/Hour),High byte: Day, range 1–31; Low byte: Hour, range 0–23
Time (Minute/Second),High byte: Minute, range 0–59; Low byte: Second, range 0–59
632NumRStandby timeoutStandby Timeout,For E2000G2, the timeout before automatically entering Off-grid Deep Sleep. Set to 0 to disable automatic entry into Off-grid Deep Sleep.
35001NumRDeep Sleep start Time hour-minDeep Sleep Schedule Start Time,Format example: 0x121E = 18:30. High byte = Hour (0–23), Low byte = Minute (0–59).
35001UINTWDeep Sleep start Time hour-minDeep Sleep Schedule Start Time,Format example: 0x121E = 18:30. High byte = Hour (0–23), Low byte = Minute (0–59).
35002NumRDeep Sleep stop Time hour-minDeep Sleep Schedule End Time,Format example: 0x121E = 18:30. High byte = Hour (0–23), Low byte = Minute (0–59).
35002UINTWDeep Sleep stop Time hour-minDeep Sleep Schedule End Time,Format example: 0x121E = 18:30. High byte = Hour (0–23), Low byte = Minute (0–59).
7171NumRLED light strip enable0:Disable
1:Enable
Front Panel LED Light Strip Control
35005EnumWLED light strip enable0:LED Light Strip Off
1:LED Light Strip On
2:LED Low-power Mode (50% brightness)
Front Panel LED Light Strip Control
8646NumRDay‌Force Full Charge Interval0-60
0:OFF
Forced Full Charge Interval,Configurable range: 0–60 days. 0 = Disable automatic full charge. Default = 0.
8646UINTW‌Force Full Charge IntervalForced Full Charge Interval,Configurable range: 0–60 days. 0 = Disable automatic full charge. Default = 0.
8647NumRTime‌Force Full Charge Start TimeDEC-->HEX
H:hour
L:minute
Forced Full Charge Start Time,Default: 00:00. High byte = Hour (0–23), Low byte = Minute (0–59).
8647UINTW‌Force Full Charge Start TimeForced Full Charge Start Time,Default: 00:00. High byte = Hour (0–23), Low byte = Minute (0–59).
2802NumRWForced AC charge powerAC Charging Power,Charging power when battery SOC falls below Backup SOC. Configurable range: 100–2400 W.
2802UINTWForced AC charge powerAC Charging Power,Charging power when battery SOC falls below Backup SOC. Configurable range: 100–2400 W.
System / Mode
7101EnumRSystemMode1:Self-consumed Prioritized
4:real-time control
5:Charge/Discharge Schedule
System operating mode (read/write)
4EnumWSystemMode1:Self-Consumption Mode
4:Real-time Control Mode
6:Custom Time Control Mode (corresponding to control parameter registers 7300–7419)
System operating mode (read/write)
6107EnumRRealtime Control Order0:Standby
1:Charge
2:Discharge
Real-time control command
6109NumRWRealtime Control PowerReal-time control power,Configurable range: 0–3600 W (single unit); 0–10800 W (parallel system)
6108NumR%Realtime Control end SOCReal-time control end SoC,Range: 0–100%
26000NumRWLoad point 1Simulated load for Time Slot 1 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12197UINTWLoad point 1Simulated load for Time Slot 1 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26001NumRWLoad point 2Simulated load for Time Slot 2 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12198UINTWLoad point 2Simulated load for Time Slot 2 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26002NumRWLoad point 3Simulated load for Time Slot 3 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12199UINTWLoad point 3Simulated load for Time Slot 3 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26003NumRWLoad point 4Simulated load for Time Slot 4 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12200UINTWLoad point 4Simulated load for Time Slot 4 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26004NumRWLoad point 5Simulated load for Time Slot 5 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12201UINTWLoad point 5Simulated load for Time Slot 5 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26005NumRWLoad point 6Simulated load for Time Slot 6 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12202UINTWLoad point 6Simulated load for Time Slot 6 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26006NumRWLoad point 7Simulated load for Time Slot 7 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12203UINTWLoad point 7Simulated load for Time Slot 7 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26007NumRWLoad point 8Simulated load for Time Slot 8 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12204UINTWLoad point 8Simulated load for Time Slot 8 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26008NumRWLoad point 9Simulated load for Time Slot 9 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12205UINTWLoad point 9Simulated load for Time Slot 9 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26009NumRWLoad point 10Simulated load for Time Slot 10 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12206UINTWLoad point 10Simulated load for Time Slot 10 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26010NumRWLoad point 11Simulated load for Time Slot 11 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12207UINTWLoad point 11Simulated load for Time Slot 11 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26011NumRWLoad point 12Simulated load for Time Slot 12 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12208UINTWLoad point 12Simulated load for Time Slot 12 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26012NumRWLoad point 13Simulated load for Time Slot 13 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12209UINTWLoad point 13Simulated load for Time Slot 13 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26013NumRWLoad point 14Simulated load for Time Slot 14 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12210UINTWLoad point 14Simulated load for Time Slot 14 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26014NumRWLoad point 15Simulated load for Time Slot 15 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12211UINTWLoad point 15Simulated load for Time Slot 15 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26015NumRWLoad point 16Simulated load for Time Slot 16 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12212UINTWLoad point 16Simulated load for Time Slot 16 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26016NumRWLoad point 17Simulated load for Time Slot 17 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12213UINTWLoad point 17Simulated load for Time Slot 17 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26017NumRWLoad point 18Simulated load for Time Slot 18 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12214UINTWLoad point 18Simulated load for Time Slot 18 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26018NumRWLoad point 19Simulated load for Time Slot 19 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12215UINTWLoad point 19Simulated load for Time Slot 19 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26019NumRWLoad point 20Simulated load for Time Slot 20 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12216UINTWLoad point 20Simulated load for Time Slot 20 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26020NumRWLoad point 21Simulated load for Time Slot 21 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12217UINTWLoad point 21Simulated load for Time Slot 21 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26021NumRWLoad point 22Simulated load for Time Slot 22 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12218UINTWLoad point 22Simulated load for Time Slot 22 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26022NumRWLoad point 23Simulated load for Time Slot 23 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12219UINTWLoad point 23Simulated load for Time Slot 23 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26023NumRWLoad point 24Simulated load for Time Slot 24 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12220UINTWLoad point 24Simulated load for Time Slot 24 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26024NumRWLoad point 25Simulated load for Time Slot 25 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12221UINTWLoad point 25Simulated load for Time Slot 25 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26025NumRWLoad point 26Simulated load for Time Slot 26 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12222UINTWLoad point 26Simulated load for Time Slot 26 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26026NumRWLoad point 27Simulated load for Time Slot 27 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12223UINTWLoad point 27Simulated load for Time Slot 27 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26027NumRWLoad point 28Simulated load for Time Slot 28 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12224UINTWLoad point 28Simulated load for Time Slot 28 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26028NumRWLoad point 29Simulated load for Time Slot 29 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12225UINTWLoad point 29Simulated load for Time Slot 29 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26029NumRWLoad point 30Simulated load for Time Slot 30 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12226UINTWLoad point 30Simulated load for Time Slot 30 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26030NumRWLoad point 31Simulated load for Time Slot 31 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12227UINTWLoad point 31Simulated load for Time Slot 31 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26031NumRWLoad point 32Simulated load for Time Slot 32 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12228UINTWLoad point 32Simulated load for Time Slot 32 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26032NumRWLoad point 33Simulated load for Time Slot 33 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12229UINTWLoad point 33Simulated load for Time Slot 33 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26033NumRWLoad point 34Simulated load for Time Slot 34 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12230UINTWLoad point 34Simulated load for Time Slot 34 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26034NumRWLoad point 35Simulated load for Time Slot 35 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12231UINTWLoad point 35Simulated load for Time Slot 35 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26035NumRWLoad point 36Simulated load for Time Slot 36 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12232UINTWLoad point 36Simulated load for Time Slot 36 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26036NumRWLoad point 37Simulated load for Time Slot 37 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12233UINTWLoad point 37Simulated load for Time Slot 37 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26037NumRWLoad point 38Simulated load for Time Slot 38 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12234UINTWLoad point 38Simulated load for Time Slot 38 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26038NumRWLoad point 39Simulated load for Time Slot 39 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12235UINTWLoad point 39Simulated load for Time Slot 39 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26039NumRWLoad point 40Simulated load for Time Slot 40 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12236UINTWLoad point 40Simulated load for Time Slot 40 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26040NumRWLoad point 41Simulated load for Time Slot 41 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12237UINTWLoad point 41Simulated load for Time Slot 41 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26041NumRWLoad point 42Simulated load for Time Slot 42 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12238UINTWLoad point 42Simulated load for Time Slot 42 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26042NumRWLoad point 43Simulated load for Time Slot 43 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12239UINTWLoad point 43Simulated load for Time Slot 43 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26043NumRWLoad point 44Simulated load for Time Slot 44 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12240UINTWLoad point 44Simulated load for Time Slot 44 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26044NumRWLoad point 45Simulated load for Time Slot 45 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12241UINTWLoad point 45Simulated load for Time Slot 45 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26045NumRWLoad point 46Simulated load for Time Slot 46 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12242UINTWLoad point 46Simulated load for Time Slot 46 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26046NumRWLoad point 47Simulated load for Time Slot 47 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12243UINTWLoad point 47Simulated load for Time Slot 47 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
26047NumRWLoad point 48Simulated load for Time Slot 48 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
12244UINTWLoad point 48Simulated load for Time Slot 48 (30-minute interval, 48 time slots in total. For simplicity, only the first and last time slots are listed.)
Real-Time Control
 and System Parameter Configuration / Setting
47005EnumWMode Setting1:Self-consumed prioritized
4:real-time control
5:charge/discharge Schedule
47015UINTWState Setting(Only available in real-time control)0:Standby
1:Charging
2:Discharging
47016INTWWPower Setting(Only available in real-time control)MAX Charging: 50-2400
MAX Discharging:50-2400
47017UINTW%SOC Settingt(Only available in real-time control)5-100
1147INTWWMax AC Output Power SettingSingle Unit: 50–2400 (50–3600)

Dual Wireless Parallel: 50–4800 (50–7200)

Triple Wireless Parallel: 50–7200 (50–10800)

Wired Parallel: 50–3600
Single Unit: Maximum output of 2400W (3600W when bypass-connected to microinverters). Supports up to 3 units in parallel.
1146INTWWFeed-in Power Limit Setting50-2400
1143UINTWGrid Charging Setting0:Disable
1:Enable
1138INTWWInverter Input Limit SettingSingle unit: 50–2400

Two units (wireless parallel): 50–4800

Three units (wireless parallel): 50–7200

Wired parallel: 50–3600
Single unit: max 2400; up to 3 units in parallel.
1EnumWLoad Setting1:Smart Plug
2:Meter
3:Key Load
4:Custom
7266EnumWBypass Setting0:Disable
1:Enable
1142INTW%Backup SOC Setting5-100
7265EnumWLight Setting0:Disable
1:Enable
SN
0StringRDevice SN
System Operating Information
2101NumRWTotal AC Iutput Power
2108NumRWTotal AC Output Power
Cluster Information
606EnumRMaster-slave identification1000:Master
1001:Slave
1002:None
Electrical Energy Information
2104NumRKWhTotal AC Output EnergyComprehensive electrical energy, including(DC+AC+Bypass)
2105NumRKWhTotal off-grid bypass output energyTotal electrical energy of off-grid bypass discharge
1505NumRWhCumulative Production
Battery Pack Operating Parameters
6002NumR%Battery SOC Total
9000NumR%Batt SOC-MB
9012NumRBatt Temp-MB
9009NumRVBatt Cell1 V-MBPG1200Series/PG2000Series/PG3000Series
9011NumRVBatt Cell2 V-MBPG1200Series/PG2000Series/PG3000Series
9016NumR%Batt SOC-Pack1
9030NumRBatt Temp-Pack1
9021NumRVBatt Cell1 V--Pack1SFA/PFA//SFA/PFA_G2//SFA/PFA_G3
9023NumRVBatt Cell2 V--Pack1SFA/PFA//SFA/PFA_G2//SFA/PFA_G3
9035NumR%Batt SOC-Pack2
9049NumRBatt Temp-Pack2
9040NumRVBatt Cell1 V-Pack2SFA/PFA//SFA/PFA_G2//SFA/PFA_G3
9042NumRVBatt Cell2 V-Pack2SFA/PFA//SFA/PFA_G2//SFA/PFA_G3
9054NumR%Batt SOC-Pack3
9068NumRBatt Temp-Pack3
9059NumRVBatt Cell1 V-Pack3SFA/PFA//SFA/PFA_G2//SFA/PFA_G3
9061NumRVBatt Cell2 V-Pack3SFA/PFA//SFA/PFA_G2//SFA/PFA_G3
9149NumR%Batt SOC-Pack4
9163NumRBatt Temp-Pack4
9154NumRVBatt Cell1 V-Pack4SFA/PFA//SFA/PFA_G2//SFA/PFA_G3
9156NumRVBatt Cell2 V-Pack4SFA/PFA//SFA/PFA_G2//SFA/PFA_G3
9202NumR%Batt SOC-Pack5
9216NumRBatt Temp-Pack5
9219NumRVBatt Cell1 V-Pack5SFA/PFA//SFA/PFA_G2//SFA/PFA_G3
9222NumRVBatt Cell2 V-Pack5SFA/PFA//SFA/PFA_G2//SFA/PFA_G3
PV Operating Parameters
1501NumRWTotal DC Output Power