PG2000Series
Scope
This firmware is released by product series, not named after a single model. The following models in the same series share the same firmware set:
SolidFlex 2000, SolidFlex 2000Eco, PowerFlex 2000, PowerFlex 2000Eco
The firmware package contains the firmware of the CMS, Pfile, EMS, BMS MB, INV, DCDC modules. Each module is updated independently, so refer to the relevant section as needed.
CMS
| Release Date | Version | Update Summary |
|---|---|---|
| 2026/10/19 | V1500.0B.0041 | 1. Fixed an issue where data could occasionally not be received after LoRa meter pairing 2. Optimized P1 meter communication anomalies 3. Optimized part of the communication logic |
| 2026/08/31 | V140E.0B.003E | 1. Optimized local access logic for third‑party inverters 2.Optimized parallel‑operation logic |
| 2026/06/30 | V140C.0B.0038 | 1. Optimized operation logic |
| 2026/05/07 | V140C.0B.0036 | 1. Optimized LoRa communication logic |
| 2026/05/07 | V140B.0B.0035 | 1. Optimized communication logic |
| 2026/04/10 | V140A.0A.0034 | 1. Added minute-level custom scheduling 2. Added support for third-party MQTT integration (not yet supported in App) 3. Added Modbus TCP cloud access (not yet supported in App) 4. Changed dynamic electricity pricing interval to 15 minutes 5. Optimized Wi-Fi and LoRa communication logic 6. Removed 10s long-press Wi-Fi reset function and moved it to App (not yet supported in App) |
| 2026/03/03 | V1408.09.0031 | 1. Added support for Stromleser energy meter (optical reader) 2. Added support for HomeWizard P1 meter 3. Added support for Shelly Plug Gen1 4. Added meter offset configuration 5. Optimized communication logic |
| 2026/01/15 | V1407.08.002F | 1. Optimized OpenData API logic |
| 2026/01/15 | V1406.07.002E | 1. Optimized communication logic |
| 2025/12/12 | V1406.07.002B | 1. Added support for Solarman smart plug, Shelly Plug S MTR Gen3, Shelly 3EM 2. Optimized system operation logic |
| 2025/10/27 | V1401.05.0022 | 1. Optimized parallel operation and OpenData |
| 2025/09/24 | V1400.04.001F | 1. Added support for Solarman P1 meter integration 2. Optimized OpenData control logic 3. Optimized version number format |
| 2025/07/31 | V1.3.0A_R00D.032_M4801_00000019 | 1. Optimized 4G/Wi-Fi resource management 2. Improved linked device signal handling 3. Extended device compatibility: added support for SOLARMAN meters 4. Enhanced system stability 5. Optimized Bluetooth provisioning |
| 2025/05/29 | V1.3.07_R00D.002_M4801_00000014 | / |
Pfile
| Release Date | Version | Update Summary |
|---|---|---|
| 2026/10/20 | V0D.00.25 | 1. Added some parameters |
| 2026/10/19 | V0D.00.24 | 1. Optimized some parameters |
| 2026/09/20 | V0D.00.23 | 1. Optimized some parameters |
| 2026/08/31 | V0D.00.22 | 1. Optimized some parameters |
| 2026/06/30 | V0D.00.20 | 1. Optimized some parameters |
| 2026/05/25 | V0D.00.19 | 1. Optimized some parameters |
| 2026/05/06 | V0D.00.18 | 1. Optimized some parameters |
| 2026/01/14 | V0D.00.14 | 1. Optimized battery temperature status display |
| 2026/01/09 | V0D.00.13 | 1. Optimized battery temperature status display |
| 2025/12/25 | V0D.00.11 | 1. Added AC charging power setting |
| 2025/11/14 | V0D.00.08 | 1. Optimized main unit LED strip control |
| 2025/10/27 | V0D.00.06 | 1. Added register points for battery pack 6, AC-coupled energy, standby-to-sleep control, bypass enable, and grid/off-grid output energy 2. Modified PV4 alarm code reporting point 3. Removed duplicate LED control point |
| 2025/09/24 | V0D.00.03 | 1. Added control flags 2. Optimized calculation logic |
EMS
| Release Date | Version | Update Summary |
|---|---|---|
| 2026/10/12 | V1.01.15 | 1. Optimized scenarios with directly connected PV in parallel operation 2. Fixed an issue where charging did not resume after weak light recovery from deep standby |
| 2026/08/13 | V1.01.12 | 1. Optimized the operating logic for cluster system scenarios 2.Optimized some known issues |
| 2026/05/12 | V1.01.08 | 1. Optimized the operating logic for cluster system scenarios |
| 2026/02/11 | V1.01.03 | 1. Optimized forced charging logic 2. Optimized scheduling time slot configuration 3. Optimized low-temperature battery heating logic 4. Optimized parallel operation logic 5. Added support for PFA4000 battery pack 6. Fixed issue where deep standby could not be entered under certain conditions |
| 2026/01/21 | V1.00.58 | 1. Optimized firmware upgrade timing 2. Optimized parallel power regulation 3. Added automatic charging when export is detected while AC charging is disabled 4. Added battery standby logic |
| 2025/12/10 | V1.00.57 | 1. Optimized PV power allocation in parallel mode 2. Improved PV priority in real-time control mode 3. Optimized upgrade logic 4. Added exit from deep standby via short press |
| 2025/11/28 | V1.00.55 | 1. Optimized upgrade logic |
| 2025/11/04 | V1.00.50 | 1. Optimized deep standby logic (standby power: 20W with bypass ON, 8W with bypass OFF) 2. Optimized LED animation during shutdown 3. Optimized backup SOC logic 4. Optimized upgrade logic 5. Optimized PV logic 6. Optimized standby parameters in real-time control mode 7. Improved overall power consumption 8. Added support for fifth expansion battery pack (hardware supported, App not yet supported) |
| 2025/10/14 | V1.00.48 | 1. Default EPS mode for off-grid port after power-on 2. Added critical load mode (not yet in App) 3. Added periodic full-charge calibration every 15 days 4. Grid power defined as AC line power 5. Added real-time control mode (not yet in App) 6. Optimized deep standby 7. Optimized parallel operation logic 8. Optimized standby power |
| 2025/08/04 | V1.00.43 | 1. Added parallel operation, grid settings, and increased grid power limit to 3600W. 2. Added LED strip & bypass relay control; optimized LED animation. 3. Increased discharge to 0.6P; optimized SOC distribution; default AC charge 2400W; fixed micro-inverter control. 4. Lowered standby threshold to 2.8%; optimized recharge logic, MOS thermal control, and inter-pack power strategy. 5. Improved overload protection (longer delay to 30s, better margin, no cascade faults). 6. EMS upgrade allowed at SOC ≥ 5%; added shutdown logging & optimized storage performance. 7. Added shutdown reporting (reason/time/count); improved real-time & time control modes |
| 2025/06/17 | V1.00.35 | / |
| 2025/06/04 | V1.00.32 | / |
BMS MB
| Release Date | Version | Update Summary |
|---|---|---|
| 2026/07/22 | V1.00.49 | 1. Optimized operating logic |
| 2026/05/12 | V1.00.45 | 1. Optimized battery protection and operating logic |
| 2026/02/11 | V1.00.42 | 1. Optimized SOC algorithm |
| 2026/01/21 | V1.00.38 | 1. Optimized SOC algorithm |
| 2025/11/28 | V1.00.35 | 1. Optimized upgrade logic |
| 2025/10/04 | V1.00.33 | 1. Optimized self-check logic 2. Optimized standby power 3. Added pre-charge logic |
| 2025/07/31 | V1.00.30 | 1. Optimized charging detection, improved communication stability, enhanced discharge protection |
| 2025/06/16 | V1.00.25 | / |
| 2025/05/30 | V1.00.22 | / |
INV
| Release Date | Version | Update Summary |
|---|---|---|
| 2026/09/30 | V1.43 | 1. Fixed an issue where the bypass port could disconnect under certain conditions 2. Optimized inverter operating logic |
| 2026/07/22 | V1.41 | 1. Optimized operating logic under weak PV light (not applicable to ECO models) |
| 2026/05/12 | V1.38 | 1. Added support for off-grid microinverters (max: 1200) 2. Optimized the issue where the grid relay could occasionally fail to close under certain operating conditions. 3. Optimized the issue where an abnormal alarm could occasionally occur after PV charging reached full capacity. |
| 2026/04/10 | V1.36 | 1. Optimized inverter issue where it may not charge/discharge during grid-tied operation |
| 2026/02/11 | V1.35 | 1. Optimized charging logic |
| 2026/01/21 | V1.34 | 1. Fixed issue where bypass may disconnect under certain conditions |
| 2025/12/10 | V1.32 | 1. Optimized real-time control mode |
| 2025/11/04 | V1.30 | 1. Added support for fifth expansion battery pack (not yet supported in App, hardware fully functional) |
| 2025/10/21 | V1.29 | / |
| 2025/10/04 | V1.28 | 1. Optimized islanding protection logic 2. Optimized off-grid discharge logic 3. Optimized derating logic |
| 2025/09/16 | V1.22 | / |
| 2025/07/08 | V1.21 | Optimized charging; improved undervoltage protection; upgraded overcurrent protection; adapted to multiple regional regulations; enhanced off-grid control; improved weak grid performance; default compliance settings |
| 2025/06/02 | V1.16 | / |
DCDC
| Release Date | Version | Update Summary |
|---|---|---|
| 2026/07/22 | V1.01.77 | 1. Optimized operating logic |
| 2026/05/29 | V1.01.75 | 1. Optimized the issue where charging power could occasionally be limited when multiple battery packs were charged |
| 2026/05/10 | V1.01.73 | 1. Optimized operating logic |
| 2026/03/20 | V1.01.64 | 1. Fixed occasional communication loss of battery packs during deep standby in multi-pack systems |
| 2026/03/04 | V1.01.62 | 1. Optimized battery pack communication |
| 2026/02/11 | V1.01.61 | 1. Optimized battery pack communication |
| 2026/01/21 | V1.01.59 | 1. Fixed SOC imbalance caused by low-power discharge |
| 2025/11/28 | V1.01.54 | 1. Fixed PV limitation issues in some conditions 2. Optimized upgrade logic |
| 2025/11/04 | V1.01.51 | 1. Optimized bypass port logic |
| 2025/10/14 | V1.01.48 | 1. Optimized PV charging logic 2. Optimized heating film operating logic |
| 2025/08/27 | V1.01.39 | / |
| 2025/07/31 | V1.01.36 | 1. Added reverse current protection, optimized discharge power, fixed charging overcurrent issues, added intelligent low-light detection, enhanced overload protection |
| 2025/06/17 | V1.01.28 | / |
| 2025/06/04 | V1.01.23 | / |