BK1600
Scope
This firmware is released by product series, not named after a single model. The following models in the same series share the same firmware set:
Indevolt BK1600
The firmware package contains the firmware of the CMS, Pfile, EMS, BMS, MPPT, INV modules. Each module is updated independently, so refer to the relevant section as needed.
CMS
| Release Date | Version | Update Summary |
|---|---|---|
| 2026/09/16 | V140E.12.104C | 1. Added meter offset configuration 2. Added Shelly smart plug control switch 3. Added support for P1 meter 4. Optimized OpenData HTTP API 5. Optimized communication stability |
| 2026/03/06 | V1408.0C.104A | 1. Added support for Stromleser meter (optical reader) 2. Added support for HomeWizard P1 meter 3. Added support for Shelly Plug Gen1 4. Added meter offset configuration |
| 2026/01/19 | V1407.0B.1049 | 1. Optimized communication logic |
| 2025/12/12 | V1406.0B.1047 | 1. Added support for Solarman smart plug, Shelly Plug S MTR Gen3, Shelly 3EM 2. Optimized system operation |
| 2025/10/23 | V1401.0B.0042 | 1. Optimized OpenData 2. Optimized system operation |
| 2025/07/22 | V130A.09.003A | / |
| 2025/06/24 | V1.3.09_R006.062_M4848_00000034 | / |
| 2024/11/25 | V1.3_R006.002_M4848_00000021 | / |
Pfile
| Release Date | Version | Update Summary |
|---|---|---|
| 2026/08/12 | V06.00.12 | Added full-charge calibration setting |
| 2025/12/29 | V06.00.09 | Added bypass control switch |
| 2025/11/14 | V06.00.08 | Added bypass control switch |
| 2025/09/02 | V06.00.06 | / |
| 2024/11/20 | V06.00.05 | 1. Updated battery data points 2. Optimized scheduling logic |
EMS
| Release Date | Version | Update Summary |
|---|---|---|
| 2026/09/16 | V1.00.20 | 1. Added AC charging switch 2. Fixed an issue where PV excess power could exceed the export limit after battery full charge in time schedule mode 3. Added reverse power charging switch |
| 2026/05/22 | V1.00.19 | 1. Optimized power calculation 2. Optimized PV operating logic when SOC reaches 100% 3. Added an AC charging enable option that is effective only when SOC is below 5% 4. Added an Auto Full Charge switch |
| 2026/02/09 | V1.00.16 | 1. Added PV power sharing between units during parallel operation 2. Optimized real-time control logic |
| 2025/08/28 | V1.00.14 | 1. System optimization: improved multi-device stability and power allocation 2. Feature enhancement: added critical load protection, scheduled full-charge maintenance, deep standby mode (replaces shutdown), extending battery lifespan 3. User experience improvement: more flexible wake-up conditions and smarter grid/off-grid operation 4. Logging & upgrade: added shutdown records; settings retained during upgrades 5. Protocol updated to latest internal communication version |
| 2025/06/26 | V1.00.13 | / |
| 2025/06/11 | V1.00.12 | / |
| 2024/11/26 | V1.00.09 | / |
BMS
| Release Date | Version | Update Summary |
|---|---|---|
| 2025/06/11 | V1.0.35 | Improved SOC accuracy during standby |
| 2024/10/31 | V1.0.34 | / |
MPPT
| Release Date | Version |
|---|---|
| 2025/09/29 | V3.17 |
| 2025/06/11 | V3.16 |
| 2024/08/03 | V3.14 |
INV
| Release Date | Version | Update Summary |
|---|---|---|
| 2026/07/22 | V1.22 | 1. Optimized relay zero-crossing turn-on 2. Optimized relay operation during charge/discharge switching to prevent relay shutdown 3. Limited the minimum frequency of DCDC hiccup protection to 100K |
| 2026/05/22 | V1.21 | 1. Optimized the grid-tied relay operating logic |
| 2025/05/08 | V1.20 | / |
| 2025/05/06 | V1.19 | / |
| 2024/08/14 | V1.18 | 1. Optimized DC/DC charging loop 2. Optimized data reporting filter |